{"id":77681,"date":"2026-10-25T19:50:47","date_gmt":"2026-10-25T19:50:47","guid":{"rendered":"https:\/\/servicenternetwork.com\/tienda\/producto\/detector-controlador-y-transductor-de-dioxido-de-carbono-co2-para-panel-de-deteccion-de-incendio\/"},"modified":"2026-10-25T19:50:47","modified_gmt":"2026-10-25T19:50:47","slug":"detector-controlador-y-transductor-de-dioxido-de-carbono-co2-para-panel-de-deteccion-de-incendio","status":"publish","type":"product","link":"https:\/\/servicenternetwork.com\/tienda\/producto\/detector-controlador-y-transductor-de-dioxido-de-carbono-co2-para-panel-de-deteccion-de-incendio\/","title":{"rendered":"Detector, Controlador y Transductor de Di\u00f3xido de Carbono (CO2) para Panel de Detecci\u00f3n de Incendio"},"content":{"rendered":"<div style=\"width: 100%;max-width: 1200px;margin: 0 auto;font-family: sans-serif;line-height: 1.6;color: inherit;background-color: transparent\"> <!-- ========== HERO ========== --> <\/p>\n<div style=\"text-align: center;padding: 40px 20px 10px 20px;margin-bottom: 40px\">\n<p style=\"font-size: 13px;letter-spacing: 3px;text-transform: uppercase;opacity: 0.6;margin: 0 0 16px 0;color: inherit\">MACURCO &#183; CD6M &#183; DETECCI&Oacute;N DE CO2<\/p>\n<h2 style=\"font-size: 44px;line-height: 1.12;margin: 0 0 20px 0;font-weight: bold;color: inherit\">El aire se mide.<br \/>La ventilaci&oacute;n responde.<\/h2>\n<p style=\"max-width: 780px;margin: 0 auto 34px auto;font-size: 17px;color: inherit;opacity: 0.85\">El CD6M vigila el di&oacute;xido de carbono de 0 a 2000 ppm y act&uacute;a antes de que el nivel se salga de control: enciende el extractor&amp;comma; avisa al panel y mantiene el espacio respirable. Detector&amp;comma; controlador y transductor en un solo equipo&amp;comma; listo para paneles de detecci&oacute;n de incendio.<\/p>\n<p> <img decoding=\"async\" style=\"width: 100%;max-width: 700px;height: auto;border-radius: 14px;0.3)\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/BancoFotografiasSyscom\/AI\/UPSCALE\/214881\/portada_0S2000.PNG\" alt=\"Detector de CO2 Macurco CD6M\"> <\/div>\n<p> <!-- ========== STATS RIBBON ========== --> <\/p>\n<div style=\"display: flex;flex-wrap: wrap;gap: 18px;justify-content: center;margin-bottom: 60px;padding: 28px 10px;0.3);0.3)\">\n<div style=\"flex: 1 1 150px;min-width: 140px;text-align: center\">\n<div style=\"font-size: 28px;font-weight: bold;color: inherit\">0-2000<\/div>\n<div style=\"font-size: 12px;letter-spacing: 1.5px;text-transform: uppercase;opacity: 0.6;color: inherit\">ppm de medici&oacute;n<\/div>\n<\/p><\/div>\n<div style=\"flex: 1 1 150px;min-width: 140px;text-align: center\">\n<div style=\"font-size: 28px;font-weight: bold;color: inherit\">5 A<\/div>\n<div style=\"font-size: 12px;letter-spacing: 1.5px;text-transform: uppercase;opacity: 0.6;color: inherit\">relevador de ventilador<\/div>\n<\/p><\/div>\n<div style=\"flex: 1 1 150px;min-width: 140px;text-align: center\">\n<div style=\"font-size: 28px;font-weight: bold;color: inherit\">4-20 mA<\/div>\n<div style=\"font-size: 12px;letter-spacing: 1.5px;text-transform: uppercase;opacity: 0.6;color: inherit\">lazo de corriente<\/div>\n<\/p><\/div>\n<div style=\"flex: 1 1 150px;min-width: 140px;text-align: center\">\n<div style=\"font-size: 28px;font-weight: bold;color: inherit\">600-1500<\/div>\n<div style=\"font-size: 12px;letter-spacing: 1.5px;text-transform: uppercase;opacity: 0.6;color: inherit\">ppm de activaci&oacute;n<\/div>\n<\/p><\/div>\n<div style=\"flex: 1 1 150px;min-width: 140px;text-align: center\">\n<div style=\"font-size: 28px;font-weight: bold;color: inherit\">-18 a 52 &deg;C<\/div>\n<div style=\"font-size: 12px;letter-spacing: 1.5px;text-transform: uppercase;opacity: 0.6;color: inherit\">operaci&oacute;n continua<\/div>\n<\/p><\/div>\n<div style=\"flex: 1 1 150px;min-width: 140px;text-align: center\">\n<div style=\"font-size: 28px;font-weight: bold;color: inherit\">ETL<\/div>\n<div style=\"font-size: 12px;letter-spacing: 1.5px;text-transform: uppercase;opacity: 0.6;color: inherit\">UL 61010-1<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p> <!-- ========== PILAR 1 ========== --> <\/p>\n<div style=\"display: flex;flex-wrap: wrap;gap: 40px;align-items: center;margin-bottom: 60px\">\n<div style=\"flex: 1 1 340px;min-width: 300px\">\n<p style=\"font-size: 12px;letter-spacing: 3px;text-transform: uppercase;opacity: 0.6;margin: 0 0 10px 0;color: inherit\">Control autom&aacute;tico<\/p>\n<h3 style=\"font-size: 30px;line-height: 1.2;margin: 0 0 16px 0;font-weight: bold;color: inherit\">Ventilaci&oacute;n que reacciona sola.<\/h3>\n<p style=\"font-size: 16px;color: inherit;opacity: 0.85;margin: 0 0 12px 0\">En salas llenas&amp;comma; cocinas y cuartos de m&aacute;quinas el CO2 sube r&aacute;pido. El CD6M activa el relevador del ventilador en el umbral que elijas: de 600 a 1500 ppm en pasos de 100.<\/p>\n<p style=\"font-size: 16px;color: inherit;opacity: 0.85;margin: 0\">Retardo de 0 a 10 minutos y tiempo m&iacute;nimo de funcionamiento de 0 a 15 minutos: el extractor trabaja lo necesario&amp;comma; ni un minuto m&aacute;s.<\/p>\n<\/p><\/div>\n<div style=\"flex: 1 1 340px;min-width: 300px\"> <img decoding=\"async\" style=\"width: 100%;height: auto;border-radius: 14px;0.3)\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/imagenes_syscom\/AI\/agente\/ai_1789161474370_chclpx.png\" alt=\"CD6M instalado en \u00e1rea comercial de bebidas\"> <\/div>\n<\/p><\/div>\n<p> <!-- ========== PILAR 2 ========== --> <\/p>\n<div style=\"display: flex;flex-wrap: wrap;gap: 40px;align-items: center;margin-bottom: 60px\">\n<div style=\"flex: 1 1 340px;min-width: 300px\"> <img decoding=\"async\" style=\"width: 100%;height: auto;border-radius: 14px;0.3)\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/BancoFotografiasSyscom\/AI\/UPSCALE\/214881\/sec_2_0S2000.PNG\" alt=\"Pantalla digital del CD6M\"> <\/div>\n<div style=\"flex: 1 1 340px;min-width: 300px\">\n<p style=\"font-size: 12px;letter-spacing: 3px;text-transform: uppercase;opacity: 0.6;margin: 0 0 10px 0;color: inherit\">Salidas y control<\/p>\n<h3 style=\"font-size: 30px;line-height: 1.2;margin: 0 0 16px 0;font-weight: bold;color: inherit\">Dos relevadores. Una salida anal&oacute;gica.<\/h3>\n<p style=\"font-size: 16px;color: inherit;opacity: 0.85;margin: 0 0 12px 0\">Un relevador SPDT de 5 A maneja ventiladores&amp;comma; v&aacute;lvulas y rejillas hasta 240 VCA. El segundo&amp;comma; de 0.5 A N.O. o N.C.&amp;comma; dispara alarmas o avisa al panel de incendio.<\/p>\n<p style=\"font-size: 16px;color: inherit;opacity: 0.85;margin: 0\">El lazo de 4-20 mA integra el detector al controlador DVP-120 de Macurco o a cualquier sistema que lea corriente.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<p> <!-- ========== PILAR 3 ========== --> <\/p>\n<div style=\"text-align: center;max-width: 820px;margin: 0 auto 30px auto\">\n<p style=\"font-size: 12px;letter-spacing: 3px;text-transform: uppercase;opacity: 0.6;margin: 0 0 10px 0;color: inherit\">Supervisi&oacute;n continua<\/p>\n<h3 style=\"font-size: 30px;line-height: 1.2;margin: 0 0 16px 0;font-weight: bold;color: inherit\">Una falla nunca queda en silencio.<\/h3>\n<p style=\"font-size: 16px;color: inherit;opacity: 0.85;margin: 0\">El dise&ntilde;o supervisado del CD6M detecta problemas del sistema y responde: activa el relevador del ventilador y el de la alarma. El espacio mantiene su respuesta aunque el detector encuentre una falla.<\/p>\n<\/p><\/div>\n<div style=\"margin-bottom: 60px\"> <img decoding=\"async\" style=\"width: 100%;height: auto;border-radius: 14px;0.3)\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/SF208P\/196708-deteccion_de_gas_(1).jpg\" alt=\"Detecci\u00f3n de gas en instalaci\u00f3n comercial\"> <\/div>\n<p> <!-- ========== PILAR 4 ========== --> <\/p>\n<div style=\"display: flex;flex-wrap: wrap;gap: 40px;align-items: center;margin-bottom: 60px\">\n<div style=\"flex: 1 1 340px;min-width: 300px\">\n<p style=\"font-size: 12px;letter-spacing: 3px;text-transform: uppercase;opacity: 0.6;margin: 0 0 10px 0;color: inherit\">Instalaci&oacute;n<\/p>\n<h3 style=\"font-size: 30px;line-height: 1.2;margin: 0 0 16px 0;font-weight: bold;color: inherit\">Montado en minutos. Calibrado de f&aacute;brica.<\/h3>\n<p style=\"font-size: 16px;color: inherit;opacity: 0.85;margin: 0 0 12px 0\">Se monta en una caja el&eacute;ctrica est&aacute;ndar de 4 x 4 pulgadas. Llega calibrado de f&aacute;brica&amp;comma; con pantalla digital&amp;comma; buzzer interno y alimentaci&oacute;n de 12 a 24 VCA o 12 a 32 VCC.<\/p>\n<p style=\"font-size: 16px;color: inherit;opacity: 0.85;margin: 0\">Tres funciones en un equipo: detector&amp;comma; controlador y transductor.<\/p>\n<\/p><\/div>\n<div style=\"flex: 1 1 340px;min-width: 300px\">\n<div style=\"display: flex;gap: 12px\"> <img decoding=\"async\" style=\"width: 50%;height: auto;border-radius: 12px;0.3)\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/BancoFotografiasSyscom\/AI\/UPSCALE\/214881\/sec_3_0S2000.PNG\" alt=\"Vista lateral izquierda del CD6M\"> <img decoding=\"async\" style=\"width: 50%;height: auto;border-radius: 12px;0.3)\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/BancoFotografiasSyscom\/AI\/UPSCALE\/214881\/sec_4_0S2000.PNG\" alt=\"Vista lateral derecha del CD6M\"> <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p> <!-- ========== APLICACIONES ========== --> <\/p>\n<div style=\"margin-bottom: 60px\">\n<p style=\"font-size: 12px;letter-spacing: 3px;text-transform: uppercase;opacity: 0.6;text-align: center;margin: 0 0 10px 0;color: inherit\">Aplicaciones<\/p>\n<h3 style=\"font-size: 30px;text-align: center;margin: 0 0 30px 0;font-weight: bold;color: inherit\">Hecho para espacios con CO2.<\/h3>\n<div style=\"display: flex;flex-wrap: wrap;gap: 20px\">\n<div style=\"flex: 1 1 220px;min-width: 200px;0.3);border-radius: 12px;padding: 22px\">\n<div style=\"font-size: 17px;font-weight: bold;margin-bottom: 8px;color: inherit\">Alimentos y bebidas<\/div>\n<div style=\"font-size: 14px;opacity: 0.75;color: inherit\">Dispensaci&oacute;n y proceso con CO2 bajo control.<\/div>\n<\/p><\/div>\n<div style=\"flex: 1 1 220px;min-width: 200px;0.3);border-radius: 12px;padding: 22px\">\n<div style=\"font-size: 17px;font-weight: bold;margin-bottom: 8px;color: inherit\">Refrigeraci&oacute;n<\/div>\n<div style=\"font-size: 14px;opacity: 0.75;color: inherit\">Cuartos fr&iacute;os y m&aacute;quinas con respuesta autom&aacute;tica.<\/div>\n<\/p><\/div>\n<div style=\"flex: 1 1 220px;min-width: 200px;0.3);border-radius: 12px;padding: 22px\">\n<div style=\"font-size: 17px;font-weight: bold;margin-bottom: 8px;color: inherit\">Invernaderos<\/div>\n<div style=\"font-size: 14px;opacity: 0.75;color: inherit\">Niveles de CO2 estables para el cultivo.<\/div>\n<\/p><\/div>\n<div style=\"flex: 1 1 220px;min-width: 200px;0.3);border-radius: 12px;padding: 22px\">\n<div style=\"font-size: 17px;font-weight: bold;margin-bottom: 8px;color: inherit\">Farmac&eacute;utica y qu&iacute;mica<\/div>\n<div style=\"font-size: 14px;opacity: 0.75;color: inherit\">Monitoreo continuo en procesos sensibles.<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p> <!-- ========== ESPECIFICACIONES ========== --> <\/p>\n<div style=\"margin-bottom: 60px\">\n<p style=\"font-size: 12px;letter-spacing: 3px;text-transform: uppercase;opacity: 0.6;text-align: center;margin: 0 0 10px 0;color: inherit\">Especificaciones<\/p>\n<h3 style=\"font-size: 30px;text-align: center;margin: 0 0 30px 0;font-weight: bold;color: inherit\">Cada dato&amp;comma; a la vista.<\/h3>\n<div style=\"display: flex;flex-wrap: wrap;gap: 20px\">\n<div style=\"flex: 1 1 320px;min-width: 280px;0.3);border-radius: 12px;overflow: hidden\">\n<div style=\"padding: 14px 18px;0.2);font-weight: bold;font-size: 16px;color: inherit\">Medici&oacute;n<\/div>\n<div style=\"padding: 14px 18px\">\n<dl style=\"margin: 0;font-size: 14px;color: inherit\">\n<dt style=\"font-weight: bold;margin-top: 8px\">Gas detectado<\/dt>\n<dd style=\"margin: 0 0 4px 0;opacity: 0.8\">Di&oacute;xido de carbono (CO2)<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Rango<\/dt>\n<dd style=\"margin: 0 0 4px 0;opacity: 0.8\">0-2000 ppm<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Indicaci&oacute;n<\/dt>\n<dd style=\"margin: 0 0 4px 0;opacity: 0.8\">Pantalla digital con buzzer interno<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Activaci&oacute;n del ventilador<\/dt>\n<dd style=\"margin: 0 0 4px 0;opacity: 0.8\">Seleccionable 600-1500 ppm (pasos de 100; 1000 por defecto)<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Calibraci&oacute;n<\/dt>\n<dd style=\"margin: 0;opacity: 0.8\">Calibrado de f&aacute;brica<\/dd>\n<\/dl><\/div>\n<\/p><\/div>\n<div style=\"flex: 1 1 320px;min-width: 280px;0.3);border-radius: 12px;overflow: hidden\">\n<div style=\"padding: 14px 18px;0.2);font-weight: bold;font-size: 16px;color: inherit\">Salidas y control<\/div>\n<div style=\"padding: 14px 18px\">\n<dl style=\"margin: 0;font-size: 14px;color: inherit\">\n<dt style=\"font-weight: bold;margin-top: 8px\">Relevador de ventilador<\/dt>\n<dd style=\"margin: 0 0 4px 0;opacity: 0.8\">5 A SPDT&amp;comma; 240 VCA<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Retardo del ventilador<\/dt>\n<dd style=\"margin: 0 0 4px 0;opacity: 0.8\">0&amp;comma; 1&amp;comma; 3 (defecto)&amp;comma; 5 o 10 minutos<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Tiempo m&iacute;nimo de funcionamiento<\/dt>\n<dd style=\"margin: 0 0 4px 0;opacity: 0.8\">0 (defecto)&amp;comma; 3&amp;comma; 5&amp;comma; 10 o 15 minutos<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Relevador de alarma<\/dt>\n<dd style=\"margin: 0 0 4px 0;opacity: 0.8\">0.5 A&amp;comma; 120 V&amp;comma; 60 VA&amp;comma; N.O. o N.C.<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Lazo de corriente<\/dt>\n<dd style=\"margin: 0;opacity: 0.8\">4-20 mA&amp;comma; compatible con DVP-120<\/dd>\n<\/dl><\/div>\n<\/p><\/div>\n<div style=\"flex: 1 1 320px;min-width: 280px;0.3);border-radius: 12px;overflow: hidden\">\n<div style=\"padding: 14px 18px;0.2);font-weight: bold;font-size: 16px;color: inherit\">El&eacute;ctricas<\/div>\n<div style=\"padding: 14px 18px\">\n<dl style=\"margin: 0;font-size: 14px;color: inherit\">\n<dt style=\"font-weight: bold;margin-top: 8px\">Alimentaci&oacute;n<\/dt>\n<dd style=\"margin: 0 0 4px 0;opacity: 0.8\">12 a 24 VCA o 12 a 32 VCC<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Corriente @ 24 VCC<\/dt>\n<dd style=\"margin: 0;opacity: 0.8\">75 mA en alarma; 50 mA con ventilador activo; 23 mA en reposo<\/dd>\n<\/dl><\/div>\n<\/p><\/div>\n<div style=\"flex: 1 1 320px;min-width: 280px;0.3);border-radius: 12px;overflow: hidden\">\n<div style=\"padding: 14px 18px;0.2);font-weight: bold;font-size: 16px;color: inherit\">F&iacute;sicas y ambiente<\/div>\n<div style=\"padding: 14px 18px\">\n<dl style=\"margin: 0;font-size: 14px;color: inherit\">\n<dt style=\"font-weight: bold;margin-top: 8px\">Dimensiones<\/dt>\n<dd style=\"margin: 0 0 4px 0;opacity: 0.8\">114 x 102 x 54 mm (4.49 x 4.02 x 2.13 in)<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Montaje<\/dt>\n<dd style=\"margin: 0 0 4px 0;opacity: 0.8\">Caja el&eacute;ctrica est&aacute;ndar de 4 x 4 pulgadas<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Temperatura<\/dt>\n<dd style=\"margin: 0 0 4px 0;opacity: 0.8\">-18 a 52 &deg;C<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Humedad<\/dt>\n<dd style=\"margin: 0 0 4px 0;opacity: 0.8\">10 a 90% HR sin condensaci&oacute;n<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Certificaci&oacute;n<\/dt>\n<dd style=\"margin: 0;opacity: 0.8\">ETL listado a UL 61010-1 y CAN\/CSA C22.2 No. 61010-1<\/dd>\n<\/dl><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p> <!-- ========== CIERRE ========== --> <\/p>\n<div style=\"text-align: center;padding: 30px 20px 10px 20px;0.3)\">\n<p style=\"font-size: 12px;letter-spacing: 3px;text-transform: uppercase;opacity: 0.6;margin: 0 0 10px 0;color: inherit\">MACURCO CD6M<\/p>\n<h3 style=\"font-size: 28px;margin: 0 0 14px 0;font-weight: bold;color: inherit\">Detecci&oacute;n&amp;comma; control y transducci&oacute;n. Un solo equipo.<\/h3>\n<p style=\"max-width: 700px;margin: 0 auto;font-size: 15px;opacity: 0.8;color: inherit\">Compatible con el panel de control DVP-120 de Macurco y con paneles de detecci&oacute;n de incendio. ETL listado a UL 61010-1 y CAN\/CSA C22.2 No. 61010-1. 3 a&ntilde;os de garant&iacute;a.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Marca <b>MACURCO &#8211; AERIONICS<\/b> \u00b7 Modelo <b>CD6M<\/b><\/p>\n<p>Producto original con garant\u00eda de f\u00e1brica. Precio con IVA incluido.<\/p>\n","protected":false},"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":[],"pwb-brand":[3158],"product_brand":[],"product_cat":[2832,2984,2846],"product_tag":[],"class_list":["post-77681","product","type-product","status-publish","pwb-brand-macurco-aerionics","product_cat-deteccion-de-fuego","product_cat-detectores-de-gases","product_cat-dispositivos-convencionales","first","instock","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"brands":[{"id":3158,"name":"MACURCO - AERIONICS","slug":"macurco-aerionics"}],"_links":{"self":[{"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product\/77681","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/comments?post=77681"}],"wp:attachment":[{"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/media?parent=77681"}],"wp:term":[{"taxonomy":"pwb-brand","embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/pwb-brand?post=77681"},{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product_brand?post=77681"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product_cat?post=77681"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product_tag?post=77681"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}