{"id":80550,"date":"2026-10-25T20:12:27","date_gmt":"2026-10-25T20:12:27","guid":{"rendered":"https:\/\/servicenternetwork.com\/tienda\/producto\/pdu-g6-monitoreable-y-switchable-ms-para-distribucion-de-energia-enchufe-de-entrada-iec-60309-3pne-6h-30a-32a-con-24-salidas-c13-c15-y-24-c13-c15-c19-c21-de-instalacion-vertical-240-vca-32-am\/"},"modified":"2026-10-25T20:12:27","modified_gmt":"2026-10-25T20:12:27","slug":"pdu-g6-monitoreable-y-switchable-ms-para-distribucion-de-energia-enchufe-de-entrada-iec-60309-3pne-6h-30a-32a-con-24-salidas-c13-c15-y-24-c13-c15-c19-c21-de-instalacion-vertical-240-vca-32-am","status":"publish","type":"product","link":"https:\/\/servicenternetwork.com\/tienda\/producto\/pdu-g6-monitoreable-y-switchable-ms-para-distribucion-de-energia-enchufe-de-entrada-iec-60309-3pne-6h-30a-32a-con-24-salidas-c13-c15-y-24-c13-c15-c19-c21-de-instalacion-vertical-240-vca-32-am\/","title":{"rendered":"PDU G6 Monitoreable y Switchable (MS) para Distribuci\u00f3n de Energ\u00eda, Enchufe de Entrada IEC 60309 3P+N+E 6h 30A\/32A, Con 24 Salidas C13\/C15 y 24 C13\/C15\/C19\/C21, de Instalaci\u00f3n Vertical, 240 Vca, 32 Amp"},"content":{"rendered":"<div style=\"width: 100%;margin: 0 auto;font-family: sans-serif;line-height: 1.6;color: inherit;background-color: transparent\">\n<div style=\"margin-bottom: 30px\">\n<p style=\"text-align: justify;font-size: 16px;color: inherit;opacity: 0.9\">La serie G6 iPDU de Panduit representa la evoluci&oacute;n en unidades de distribuci&oacute;n de energ&iacute;a inteligente para centros de datos&amp;comma; ofreciendo monitoreo preciso de energ&iacute;a y condiciones ambientales a nivel de rack o gabinete. Estas iPDUs est&aacute;n dise&ntilde;adas para la detecci&oacute;n continua de sobrecargas el&eacute;ctricas y condiciones ambientales que puedan poner en riesgo equipos cr&iacute;ticos de TI. Con certificaci&oacute;n USGv6&amp;comma; proporcionan datos de medici&oacute;n de energ&iacute;a integrales y precisos para optimizar el uso de recursos energ&eacute;ticos&amp;comma; facilitar decisiones informadas de planificaci&oacute;n de capacidad&amp;comma; mejorar la disponibilidad y medir la efectividad del uso de energ&iacute;a (PUE). La familia incluye las series MI (monitoreo agregado)&amp;comma; MS (monitoreo agregado y conmutaci&oacute;n a nivel de salida)&amp;comma; MPO (monitoreo a nivel de salida) y MSPO (monitoreo y conmutaci&oacute;n a nivel de salida)&amp;comma; ofreciendo una soluci&oacute;n escalable para diversas necesidades de gesti&oacute;n de energ&iacute;a en centros de datos.<\/p>\n<\/div>\n<div style=\"display: flex;flex-wrap: wrap;gap: 30px;margin-bottom: 30px\">\n<div style=\"flex: 1 1 300px;min-width: 280px\">\n<h3 style=\"font-size: 22px;border-bottom: 2px solid currentColor;padding-bottom: 5px;margin-top: 0;color: inherit;opacity: 0.8\"><span style=\"font-size: 24px\">Caracter&iacute;sticas Generales<\/span><\/h3>\n<ul style=\"padding-left: 20px;font-size: 15px;color: inherit\">\n<li style=\"margin-bottom: 5px\"><strong>Controlador Hot-Swappable:<\/strong> Reemplazo del controlador y m&oacute;dulo de visualizaci&oacute;n sin necesidad de apagar el rack.<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Redundancia de red:<\/strong> Acceso remoto a estad&iacute;sticas vitales y datos operativos en tiempo real a trav&eacute;s de dos redes seguras separadas (ideal para arrendador\/inquilino).<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Seguridad reforzada:<\/strong> NMP v3&amp;comma; TLS&amp;comma; seguridad cifrada; permite superar escaneos de seguridad est&aacute;ndar de la industria. Stack IPv6 certificado USGv6.<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Dual Ethernet 1GB:<\/strong> Negociaci&oacute;n autom&aacute;tica con switches de red de nivel de centro de datos; capacidad de conexi&oacute;n en cadena de hasta 32 iPDUs en una sola direcci&oacute;n IP usando un solo puerto de switch.<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Sensores digitales Plug &amp; Play:<\/strong> Permiten m&uacute;ltiples sensores en el mismo bus y se identifican autom&aacute;ticamente ante el controlador para simplificar la configuraci&oacute;n.<\/li>\n<li style=\"margin-bottom: 5px\"><strong>PDUs multicolor:<\/strong> Diferentes colores para simplificar la identificaci&oacute;n de alimentaci&oacute;n en esquemas de energ&iacute;a redundante.<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Interfaz web adaptable:<\/strong> Interfaz web mejorada que detecta el tipo de dispositivo (laptop&amp;comma; tableta o tel&eacute;fono inteligente) y ajusta autom&aacute;ticamente la pantalla para una experiencia &oacute;ptima.<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Densidad de salidas:<\/strong> Satisface las demandas de equipos de TI densamente empaquetados en espacio de rack o gabinete.<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Factor de forma:<\/strong> Factor de forma &oacute;ptimo que permite una utilizaci&oacute;n eficiente del espacio del rack y del flujo de aire.<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Temperatura de operaci&oacute;n:<\/strong> 60 &deg;C ambiente a plena carga para confiabilidad operativa en &aacute;reas de alta temperatura.<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Retenci&oacute;n de cables:<\/strong> Salidas innovadoras que aceptan bridas para una sujeci&oacute;n segura de cables (C13 y C19) usando una brida (Panduit PLT21-C0).<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Disyuntores:<\/strong> Protegen equipos del centro de datos al interrumpir condiciones de sobrecorriente peligrosas.<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Circuitos codificados por color:<\/strong> Identificaci&oacute;n f&aacute;cil de fase a bancos de salidas para ayudar en el aislamiento de fallas o balanceo de carga.<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Conexi&oacute;n a tierra externa del chasis:<\/strong> Cumple con los requisitos NEC y las pautas de instalaci&oacute;n para equipos de TI.<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Balanceo de carga:<\/strong> Monitoreado a trav&eacute;s de pantalla visual en oLED (solo para unidades trif&aacute;sicas).<\/li>\n<li style=\"margin-bottom: 5px\"><strong>M&uacute;ltiples opciones de enchufe de entrada:<\/strong> Una oferta completa para interoperar sin problemas con los esquemas de cableado de energ&iacute;a del edificio existentes.<\/li>\n<li style=\"margin-bottom: 5px\"><strong>M&uacute;ltiples opciones de montaje:<\/strong> Permite una puesta en marcha sencilla y flexibilidad con gabinetes Panduit y caracter&iacute;sticas de montaje est&aacute;ndar de la industria para instalaci&oacute;n en gabinetes de terceros.<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Botones de montaje:<\/strong> Permite el montaje sin herramientas de PDUs de rack para instalaciones m&aacute;s r&aacute;pidas en unidades verticales 0U.<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Medici&oacute;n soportada:<\/strong> Frecuencia&amp;comma; VA&amp;comma; PF&amp;comma; m&aacute;s amperaje&amp;comma; voltaje&amp;comma; vataje y kilovatios por hora agregados y por fase.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div style=\"display: flex;flex-wrap: wrap;gap: 20px;margin-bottom: 30px\">\n<div style=\"flex: 1 1 250px;0.4);border-radius: 8px;overflow: hidden;display: flex;flex-direction: column\">\n<div style=\"padding: 15px;0.2);font-weight: bold;font-size: 18px;color: inherit\"><span style=\"font-size: 24px\">Desempe&ntilde;o \/ Rendimiento<\/span><\/div>\n<div style=\"padding: 15px;color: inherit\">\n<ul style=\"padding-left: 20px;margin: 0;font-size: 14px;list-style-type: disc\">\n<li style=\"margin-bottom: 5px\"><strong>Voltaje de entrada:<\/strong> 100-240 VCA (monof&aacute;sico) \/ 230\/415 VCA (trif&aacute;sico)<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Corriente de entrada (por fase):<\/strong> 15 A&amp;comma; 20 A&amp;comma; 30 A&amp;comma; 50 A&amp;comma; 60 A (NA) \/ 16 A&amp;comma; 32 A&amp;comma; 63 A (Internacional)<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Potencia aparente (kVA):<\/strong> 1.4 &#8211; 44.4 kVA<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Frecuencia de entrada:<\/strong> 50\/60 Hz<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Voltaje de salida:<\/strong> 120-240 VCA<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Corriente m&aacute;xima de salida (por salida):<\/strong> IEC C13: 10 A&amp;comma; IEC C19: 16 A&amp;comma; NEMA 5-20R: 16 A<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Protecci&oacute;n contra sobrecarga:<\/strong> Disyuntores hidromagn&eacute;ticos de 5 kAIC \/ 10 kAIC (modelos 415 V NA)<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Salidas combinadas:<\/strong> Flexibilidad para usar una salida como C13\/C15 o C13\/C15\/C19\/C21; aceptan cables de bloqueo dual Panduit.<\/li>\n<li style=\"margin-bottom: 5px\"><strong>PDUs de doble clasificaci&oacute;n:<\/strong> Clasificaciones y aprobaciones NRTL para Am&eacute;rica del Norte y EMEA en el mismo n&uacute;mero de pieza.<\/li>\n<\/ul>\n<p style=\"font-size: 12px;opacity: 0.7;margin-top: 10px\">*Notas: Las especificaciones var&iacute;an seg&uacute;n el modelo y la regi&oacute;n.<\/p>\n<\/div>\n<\/div>\n<div style=\"flex: 1 1 250px;0.4);border-radius: 8px;overflow: hidden;display: flex;flex-direction: column\">\n<div style=\"padding: 15px;0.2);font-weight: bold;font-size: 18px;color: inherit\"><span style=\"font-size: 24px\">F&iacute;sicas y El&eacute;ctricas<\/span><\/div>\n<div style=\"padding: 15px;color: inherit\">\n<ul style=\"padding-left: 20px;margin: 0;font-size: 14px;list-style-type: disc\">\n<li style=\"margin-bottom: 5px\"><strong>Alimentaci&oacute;n:<\/strong> 100-240 VCA \/ 230\/415 VCA (seg&uacute;n modelo)<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Dimensiones (Ancho x Profundidad x Alto):<\/strong> 0U HALF: 52 mm x 53 mm x 917 mm (2 in x 2.1 in x 36.1 in); 0U MID: 52 mm x 53 mm x 1490 mm (2 in x 2.1 in x 58.6 in); 0U FULL: 52 mm x 53 mm x 1750 mm (2 in x 2.1 in x 69 in); 0U FULL Wide: 85 mm x 53 mm x 1750 mm (3.3 in x 2.1 in x 69 in)<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Peso:<\/strong> Variable seg&uacute;n modelo<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Temperatura de operaci&oacute;n:<\/strong> 10 &deg;C a 60 &deg;C (50 &deg;F a 140 &deg;F)<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Temperatura de almacenamiento:<\/strong> -20 &deg;C a 60 &deg;C (-4 &deg;F a 140 &deg;F)<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Humedad relativa (operaci&oacute;n):<\/strong> 10% a 90% sin condensaci&oacute;n<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Humedad relativa (almacenamiento):<\/strong> 5% a 95%<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Elevaci&oacute;n (operaci&oacute;n):<\/strong> 0 a 3000 m (0 a 10&amp;comma;000 ft)<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Elevaci&oacute;n (almacenamiento):<\/strong> 0 a 9144 m (0 a 30&amp;comma;000 ft)<\/li>\n<li style=\"margin-bottom: 5px\"><strong>Montaje:<\/strong> Vertical 0U&amp;comma; con botones de montaje sin herramientas (di&aacute;metro 18.4 mm); tambi&eacute;n disponible bot&oacute;n de 14.5 mm (P\/N: MA018).<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div style=\"flex: 1 1 250px;0.4);border-radius: 8px;overflow: hidden;display: flex;flex-direction: column\">\n<div style=\"padding: 15px;0.2);font-weight: bold;font-size: 18px;color: inherit\"><span style=\"font-size: 24px\">Contenido del Paquete<\/span><\/div>\n<div style=\"padding: 15px;color: inherit\">\n<ul style=\"padding-left: 20px;margin: 0;font-size: 14px;list-style-type: disc\">\n<li style=\"margin-bottom: 5px\">Unidad de Distribuci&oacute;n de Energ&iacute;a Inteligente G6 iPDU<\/li>\n<li style=\"margin-bottom: 5px\">Controlador y m&oacute;dulo de visualizaci&oacute;n (Hot-Swappable)<\/li>\n<li style=\"margin-bottom: 5px\">Kit de montaje (botones de montaje)<\/li>\n<li style=\"margin-bottom: 5px\">Documentaci&oacute;n del producto<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Marca <b>PANDUIT<\/b> \u00b7 Modelo <b>P48D20G<\/b><\/p>\n<p>Producto original con garant\u00eda de f\u00e1brica. Precio con IVA incluido.<\/p>\n","protected":false},"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":[],"pwb-brand":[3214],"product_brand":[],"product_cat":[2347,2346,2115],"product_tag":[],"class_list":["post-80550","product","type-product","status-publish","pwb-brand-panduit","product_cat-accesorios-para-racks-y-gabinetes-racks-y-gabinetes-radiocomunicacion","product_cat-racks-y-gabinetes-radiocomunicacion","product_cat-radiocomunicacion","first","instock","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"brands":[{"id":3214,"name":"PANDUIT","slug":"panduit"}],"_links":{"self":[{"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product\/80550","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/comments?post=80550"}],"wp:attachment":[{"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/media?parent=80550"}],"wp:term":[{"taxonomy":"pwb-brand","embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/pwb-brand?post=80550"},{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product_brand?post=80550"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product_cat?post=80550"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product_tag?post=80550"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}