{"id":83958,"date":"2026-10-25T20:32:52","date_gmt":"2026-10-25T20:32:52","guid":{"rendered":"https:\/\/servicenternetwork.com\/tienda\/producto\/switch-data-center-25g-100g-48-puertos-sfp28-25g-8-qsfp28-100g-4-0-tbps-2000-mpps-rdma-rocev2-capa-3-vxlan-evpn-spine-leaf-bgp-ospf-m-lag-pfc-ecn-lossless-ethernet-1-ru-fuentes-11-hot-swa\/"},"modified":"2026-10-25T20:32:52","modified_gmt":"2026-10-25T20:32:52","slug":"switch-data-center-25g-100g-48-puertos-sfp28-25g-8-qsfp28-100g-4-0-tbps-2000-mpps-rdma-rocev2-capa-3-vxlan-evpn-spine-leaf-bgp-ospf-m-lag-pfc-ecn-lossless-ethernet-1-ru-fuentes-11-hot-swa","status":"publish","type":"product","link":"https:\/\/servicenternetwork.com\/tienda\/producto\/switch-data-center-25g-100g-48-puertos-sfp28-25g-8-qsfp28-100g-4-0-tbps-2000-mpps-rdma-rocev2-capa-3-vxlan-evpn-spine-leaf-bgp-ospf-m-lag-pfc-ecn-lossless-ethernet-1-ru-fuentes-11-hot-swa\/","title":{"rendered":"Switch Data Center 25G\/100G \/ 48 Puertos SFP28 25G + 8 QSFP28 100G \/ 4.0 Tbps 2000 Mpps RDMA RoCEv2 \/ Capa 3 VXLAN EVPN Spine-Leaf BGP OSPF \/ M-LAG PFC ECN Lossless Ethernet \/ 1 RU Fuentes 1+1 Hot-Swap"},"content":{"rendered":"<p><!-- ========== HERO ========== --> <\/p>\n<div style=\"width: 100%;margin: 0 auto;font-family: sans-serif;line-height: 1.6;color: inherit;background-color: transparent\">\n<div style=\"position: relative;margin-bottom: 60px;text-align: center\">\n<p style=\"font-size: 13px;letter-spacing: 2px;text-transform: uppercase;opacity: 0.6;margin-bottom: 16px;color: inherit\">Ruijie &#183; RG-S6510-48VS8CQ &#183; Data Center Switch<\/p>\n<h2 style=\"font-size: 42px;font-weight: 300;margin: 0 0 16px 0;color: inherit;line-height: 1.15;letter-spacing: -0.5px\">El switch que lleva 25G\/100G a cada rack.<\/h2>\n<p style=\"font-size: 18px;max-width: 620px;margin: 0 auto 32px auto;opacity: 0.8;color: inherit;line-height: 1.5\"> 4.0 Tbps de switching. 48 puertos SFP28 25G y 8 QSFP28 100G. Todo en 1 RU. Dise&#241;ado para arquitecturas Spine-Leaf con VXLAN&amp;comma; EVPN y RDMA sobre RoCEv2. <\/p>\n<p> <img decoding=\"async\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/imagenes_syscom\/AI\/agente\/ai_1784070848568_hnt6q3.png\" style=\"width: 100%;max-width: 900px;height: auto;border-radius: 16px\" alt=\"RG-S6510-48VS8CQ\"> <\/div>\n<p> <!-- ========== STATS RIBBON ========== --> <\/p>\n<div style=\"display: flex;flex-wrap: wrap;justify-content: center;gap: 40px;padding: 28px 0;0.2);0.2);margin-bottom: 60px;text-align: center\">\n<div>\n<div style=\"font-size: 32px;font-weight: 300;color: inherit;letter-spacing: -0.5px\">4.0 Tbps<\/div>\n<div style=\"font-size: 12px;opacity: 0.5;text-transform: uppercase;letter-spacing: 1px;color: inherit\">Switching<\/div>\n<\/p><\/div>\n<div>\n<div style=\"font-size: 32px;font-weight: 300;color: inherit;letter-spacing: -0.5px\">2000 Mpps<\/div>\n<div style=\"font-size: 12px;opacity: 0.5;text-transform: uppercase;letter-spacing: 1px;color: inherit\">Forwarding<\/div>\n<\/p><\/div>\n<div>\n<div style=\"font-size: 32px;font-weight: 300;color: inherit;letter-spacing: -0.5px\">48 + 8<\/div>\n<div style=\"font-size: 12px;opacity: 0.5;text-transform: uppercase;letter-spacing: 1px;color: inherit\">25G + 100G Ports<\/div>\n<\/p><\/div>\n<div>\n<div style=\"font-size: 32px;font-weight: 300;color: inherit;letter-spacing: -0.5px\">32 MB<\/div>\n<div style=\"font-size: 12px;opacity: 0.5;text-transform: uppercase;letter-spacing: 1px;color: inherit\">Buffer<\/div>\n<\/p><\/div>\n<div>\n<div style=\"font-size: 32px;font-weight: 300;color: inherit;letter-spacing: -0.5px\">1 RU<\/div>\n<div style=\"font-size: 12px;opacity: 0.5;text-transform: uppercase;letter-spacing: 1px;color: inherit\">Form Factor<\/div>\n<\/p><\/div>\n<div>\n<div style=\"font-size: 32px;font-weight: 300;color: inherit;letter-spacing: -0.5px\">300 W<\/div>\n<div style=\"font-size: 12px;opacity: 0.5;text-transform: uppercase;letter-spacing: 1px;color: inherit\">Max Power<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p> <!-- ========== PILAR 1 ========== --> <\/p>\n<div style=\"display: flex;flex-wrap: wrap;gap: 50px;margin-bottom: 80px;align-items: center\">\n<div style=\"flex: 1 1 350px\">\n<p style=\"font-size: 12px;letter-spacing: 2px;text-transform: uppercase;opacity: 0.5;margin-bottom: 12px;color: inherit\">Rendimiento<\/p>\n<h3 style=\"font-size: 28px;font-weight: 300;margin: 0 0 16px 0;color: inherit;letter-spacing: -0.3px;line-height: 1.2\">Densidad que desaf&#237;a el espacio f&#237;sico.<\/h3>\n<p style=\"font-size: 16px;opacity: 0.8;color: inherit;line-height: 1.7\"> Cuarenta y ocho puertos SFP28 de 25G y ocho QSFP28 de 100G en un solo rack unit. Eso son 1.6 Tbps de ancho de banda agregado hacia los servidores y 800 Gbps hacia el uplink. El switching de 4.0 Tbps con 2000 Mpps de forwarding garantiza que cada puerto entregue line-rate&amp;comma; sin bloqueos&amp;comma; sin excuses. <\/p>\n<\/p><\/div>\n<div style=\"flex: 1 1 350px;text-align: center\"> <img decoding=\"async\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/BancoFotografiasSyscom\/RUIJIE\/RGS651048VS8CQ\/RGS651048VS8CQ-AD-1-p.PNG\" style=\"width: 100%;max-width: 500px;height: auto;border-radius: 12px\" alt=\"Front panel RG-S6510-48VS8CQ\"> <\/div>\n<\/p><\/div>\n<p> <!-- ========== PILAR 2 ========== --> <\/p>\n<div style=\"margin-bottom: 80px;padding: 60px 30px;border-radius: 20px;0.06)\">\n<p style=\"font-size: 12px;letter-spacing: 2px;text-transform: uppercase;opacity: 0.5;margin-bottom: 12px;color: inherit;text-align: center\">Lossless Ethernet<\/p>\n<h3 style=\"font-size: 28px;font-weight: 300;margin: 0 0 16px 0;color: inherit;letter-spacing: -0.3px;line-height: 1.2;text-align: center\">RDMA sin perder un solo paquete.<\/h3>\n<p style=\"font-size: 16px;opacity: 0.8;color: inherit;line-height: 1.7;max-width: 700px;margin: 0 auto 30px auto;text-align: center\"> RoCEv2 con PFC (Priority Flow Control) y ECN (Explicit Congestion Notification) elimina la p&#233;rdida de paquetes en entornos de almacenamiento distribuido&amp;comma; cl&#250;steres de HPC y cargas de trabajo de IA. El buffer de 32 MB con programaci&#243;n avanzada absorbe micro-r&#225;fagas sin tirar frames. Menos retransmisiones&amp;comma; m&#225;s throughput. <\/p>\n<div style=\"display: flex;flex-wrap: wrap;gap: 20px;justify-content: center\">\n<div style=\"padding: 16px 24px;border-radius: 10px;0.2);text-align: center;min-width: 140px;background-color: transparent\">\n<div style=\"font-size: 22px;font-weight: 300;color: inherit\">RoCEv2<\/div>\n<div style=\"font-size: 11px;opacity: 0.5;color: inherit\">RDMA over Converged Ethernet<\/div>\n<\/p><\/div>\n<div style=\"padding: 16px 24px;border-radius: 10px;0.2);text-align: center;min-width: 140px;background-color: transparent\">\n<div style=\"font-size: 22px;font-weight: 300;color: inherit\">PFC<\/div>\n<div style=\"font-size: 11px;opacity: 0.5;color: inherit\">Priority Flow Control<\/div>\n<\/p><\/div>\n<div style=\"padding: 16px 24px;border-radius: 10px;0.2);text-align: center;min-width: 140px;background-color: transparent\">\n<div style=\"font-size: 22px;font-weight: 300;color: inherit\">ECN<\/div>\n<div style=\"font-size: 11px;opacity: 0.5;color: inherit\">Explicit Congestion Notification<\/div>\n<\/p><\/div>\n<div style=\"padding: 16px 24px;border-radius: 10px;0.2);text-align: center;min-width: 140px;background-color: transparent\">\n<div style=\"font-size: 22px;font-weight: 300;color: inherit\">32 MB<\/div>\n<div style=\"font-size: 11px;opacity: 0.5;color: inherit\">Buffer Scheduling<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p> <!-- ========== PILAR 3 ========== --> <\/p>\n<div style=\"display: flex;flex-wrap: wrap;gap: 50px;margin-bottom: 80px;align-items: center;flex-direction: row-reverse\">\n<div style=\"flex: 1 1 350px\">\n<p style=\"font-size: 12px;letter-spacing: 2px;text-transform: uppercase;opacity: 0.5;margin-bottom: 12px;color: inherit\">Data Center Fabric<\/p>\n<h3 style=\"font-size: 28px;font-weight: 300;margin: 0 0 16px 0;color: inherit;letter-spacing: -0.3px;line-height: 1.2\">La red que se programa&amp;comma; no se configura.<\/h3>\n<p style=\"font-size: 16px;opacity: 0.8;color: inherit;line-height: 1.7\"> VXLAN routing y bridging&amp;comma; EVPN VXLAN y OpenFlow 1.3. BGP4&amp;comma; OSPFv2 y ECMP para el underlay de Capa 3. M-LAG para redundancia a nivel de dispositivo sin protocolos propietarios. Despliega arquitecturas Spine-Leaf donde cada leaf conoce la topolog&#237;a completa y responde en milisegundos. <\/p>\n<\/p><\/div>\n<div style=\"flex: 1 1 350px;text-align: center\"> <img decoding=\"async\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/RGS651032CQ\/233437-center_switches_rg-s6510-32cq_data_center_100ge.png\" style=\"width: 100%;max-width: 500px;height: auto;border-radius: 12px\" alt=\"RG-S6510 rear view\"> <\/div>\n<\/p><\/div>\n<p> <!-- ========== PILAR 4 ========== --> <\/p>\n<div style=\"display: flex;flex-wrap: wrap;gap: 50px;margin-bottom: 80px;align-items: center\">\n<div style=\"flex: 1 1 350px\">\n<p style=\"font-size: 12px;letter-spacing: 2px;text-transform: uppercase;opacity: 0.5;margin-bottom: 12px;color: inherit\">Alta Disponibilidad<\/p>\n<h3 style=\"font-size: 28px;font-weight: 300;margin: 0 0 16px 0;color: inherit;letter-spacing: -0.3px;line-height: 1.2\">Dise&#241;ado para no apagarse nunca.<\/h3>\n<p style=\"font-size: 16px;opacity: 0.8;color: inherit;line-height: 1.7\"> Fuentes de poder 1+1 y cuatro ventiladores hot-swap. VSU para virtualizar dos switches como uno solo con gesti&#243;n unificada. GR para BGP\/OSPF\/RIP&amp;comma; BFD para detecci&#243;n de fallos en sub-segundo&amp;comma; y REUP para conmutaci&#243;n dual-link. El plano de datos nunca se cae. <\/p>\n<\/p><\/div>\n<div style=\"flex: 1 1 350px;text-align: center\"> <img decoding=\"async\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/BancoFotografiasSyscom\/RUIJIE\/RGS651048VS8CQ\/RGS651048VS8CQ-AD-3-p.PNG\" style=\"width: 100%;max-width: 500px;height: auto;border-radius: 12px\" alt=\"Rear view RG-S6510-48VS8CQ\"> <\/div>\n<\/p><\/div>\n<p> <!-- ========== APLICACIONES ========== --> <\/p>\n<div style=\"margin-bottom: 80px\">\n<p style=\"font-size: 12px;letter-spacing: 2px;text-transform: uppercase;opacity: 0.5;margin-bottom: 30px;color: inherit;text-align: center\">Casos de uso<\/p>\n<div style=\"display: flex;flex-wrap: wrap;gap: 24px;justify-content: center\">\n<div style=\"flex: 1 1 200px;min-width: 180px;padding: 24px;border-radius: 14px;0.2);text-align: center;background-color: transparent\">\n<div style=\"font-size: 14px;font-weight: 500;color: inherit;margin-bottom: 6px\">Data Centers<\/div>\n<p style=\"font-size: 13px;opacity: 0.6;color: inherit;line-height: 1.5\">Leaf switches 25G\/100G para racks de alta densidad con VXLAN y EVPN.<\/p>\n<\/p><\/div>\n<div style=\"flex: 1 1 200px;min-width: 180px;padding: 24px;border-radius: 14px;0.2);text-align: center;background-color: transparent\">\n<div style=\"font-size: 14px;font-weight: 500;color: inherit;margin-bottom: 6px\">Cloud Providers<\/div>\n<p style=\"font-size: 13px;opacity: 0.6;color: inherit;line-height: 1.5\">Infraestructura multi-tenant con segmentaci&#243;n VXLAN y BGP EVPN.<\/p>\n<\/p><\/div>\n<div style=\"flex: 1 1 200px;min-width: 180px;padding: 24px;border-radius: 14px;0.2);text-align: center;background-color: transparent\">\n<div style=\"font-size: 14px;font-weight: 500;color: inherit;margin-bottom: 6px\">HPC \/ AI Clusters<\/div>\n<p style=\"font-size: 13px;opacity: 0.6;color: inherit;line-height: 1.5\">RDMA RoCEv2 para entrenamiento distribuido con baja latencia.<\/p>\n<\/p><\/div>\n<div style=\"flex: 1 1 200px;min-width: 180px;padding: 24px;border-radius: 14px;0.2);text-align: center;background-color: transparent\">\n<div style=\"font-size: 14px;font-weight: 500;color: inherit;margin-bottom: 6px\">Enterprise Core<\/div>\n<p style=\"font-size: 13px;opacity: 0.6;color: inherit;line-height: 1.5\">N&#250;cleo de campus con agregaci&#243;n 25G\/100G y M-LAG redundante.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p> <!-- ========== ESPECIFICACIONES ========== --> <\/p>\n<div style=\"margin-bottom: 80px\">\n<p style=\"font-size: 12px;letter-spacing: 2px;text-transform: uppercase;opacity: 0.5;margin-bottom: 30px;color: inherit;text-align: center\">Especificaciones t&#233;cnicas<\/p>\n<div style=\"display: flex;flex-wrap: wrap;gap: 24px\">\n<div style=\"flex: 1 1 250px;min-width: 240px;0.2);border-radius: 14px;overflow: hidden;background-color: transparent\">\n<div style=\"padding: 16px 20px;0.15);font-weight: 500;font-size: 15px;color: inherit\">Desempe&#241;o<\/div>\n<div style=\"padding: 16px 20px;color: inherit\">\n<dl style=\"margin: 0;font-size: 13px;line-height: 1.8\">\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">Switching Capacity<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">4.0 Tbps<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">Forwarding Rate<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">2000 Mpps<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">Packet Buffer<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">32 MB<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">MAC Addresses<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">96&amp;comma;000<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">VLANs<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">4&amp;comma;094<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">Jumbo Frame<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">9 KB<\/dd>\n<\/dl><\/div>\n<\/p><\/div>\n<div style=\"flex: 1 1 250px;min-width: 240px;0.2);border-radius: 14px;overflow: hidden;background-color: transparent\">\n<div style=\"padding: 16px 20px;0.15);font-weight: 500;font-size: 15px;color: inherit\">Puertos<\/div>\n<div style=\"padding: 16px 20px;color: inherit\">\n<dl style=\"margin: 0;font-size: 13px;line-height: 1.8\">\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">Service Ports<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">48 x 10G\/25G SFP28<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">Uplink Ports<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">8 x 40G\/100G QSFP28<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">Management<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">1 x RJ45 Console<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">MGMT<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">1 x RJ45 MGMT<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">USB<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">1 x USB 2.0 Type A<\/dd>\n<\/dl><\/div>\n<\/p><\/div>\n<div style=\"flex: 1 1 250px;min-width: 240px;0.2);border-radius: 14px;overflow: hidden;background-color: transparent\">\n<div style=\"padding: 16px 20px;0.15);font-weight: 500;font-size: 15px;color: inherit\">F&#237;sicas y El&#233;ctricas<\/div>\n<div style=\"padding: 16px 20px;color: inherit\">\n<dl style=\"margin: 0;font-size: 13px;line-height: 1.8\">\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">Dimensions<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">442 x 387 x 44 mm<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">Rack Units<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">1 RU<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">Weight (loaded)<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">8.2 kg (18.08 lbs)<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">Power Max<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">300 W (100-240V AC)<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">Operating Temp<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">0&#176;C to 45&#176;C<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">Cooling<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">4 x Fans&amp;comma; Front-to-Rear<\/dd>\n<\/dl><\/div>\n<\/p><\/div>\n<div style=\"flex: 1 1 250px;min-width: 240px;0.2);border-radius: 14px;overflow: hidden;background-color: transparent\">\n<div style=\"padding: 16px 20px;0.15);font-weight: 500;font-size: 15px;color: inherit\">Protocolos Capa 3<\/div>\n<div style=\"padding: 16px 20px;color: inherit\">\n<dl style=\"margin: 0;font-size: 13px;line-height: 1.8\">\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">Routing<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">BGP4&amp;comma; OSPFv2&amp;comma; RIPv1\/v2<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">IPv6<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">OSPFv3&amp;comma; RIPng&amp;comma; BGP4+<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">Multicast<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">PIM-SM\/DM\/SSM&amp;comma; IGMP<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">Redundancy<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">VRRP&amp;comma; ECMP&amp;comma; WCMP<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">SDN<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">OpenFlow 1.3<\/dd>\n<dt style=\"opacity: 0.5;font-size: 11px;text-transform: uppercase;letter-spacing: 0.5px\">Telemetry<\/dt>\n<dd style=\"margin: 0 0 10px 0;font-size: 15px;font-weight: 400\">gRPC&amp;comma; sFlow&amp;comma; INT<\/dd>\n<\/dl><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p> <!-- ========== CIERRE ========== --> <\/p>\n<div style=\"text-align: center;margin-bottom: 40px;padding: 60px 20px;border-radius: 20px;0.04)\">\n<p style=\"font-size: 12px;letter-spacing: 2px;text-transform: uppercase;opacity: 0.5;margin-bottom: 16px;color: inherit\">RG-S6510-48VS8CQ<\/p>\n<h3 style=\"font-size: 28px;font-weight: 300;margin: 0 0 16px 0;color: inherit;letter-spacing: -0.3px\">El switch que tu data center estaba esperando.<\/h3>\n<p style=\"font-size: 16px;opacity: 0.7;color: inherit;max-width: 550px;margin: 0 auto 24px auto;line-height: 1.6\"> Compatible con transceptores SFP28 25G y QSFP28 100G est&#225;ndar. Gestible v&#237;a SNMP&amp;comma; Netconf&amp;comma; CLI&amp;comma; Web y Ruijie Cloud. Tres a&#241;os de garant&#237;a SYSCOM. <\/p>\n<p> <a href=\"https:\/\/www.syscom.mx\/products\" style=\"display: inline-block;padding: 12px 32px;border-radius: 8px;0.4);color: inherit;text-decoration: none;font-size: 14px;font-weight: 500;letter-spacing: 0.3px;background-color: transparent\">Ver productos en SYSCOM<\/a> <\/div>\n<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Marca <b>RUIJIE<\/b> \u00b7 Modelo <b>RG-S6510-48VS8CQ<\/b><\/p>\n<p>Producto original con garant\u00eda de f\u00e1brica. Precio con IVA incluido.<\/p>\n","protected":false},"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":[],"pwb-brand":[3284],"product_brand":[],"product_cat":[2281,2280,2288],"product_tag":[],"class_list":["post-83958","product","type-product","status-publish","pwb-brand-ruijie","product_cat-networking","product_cat-redes-e-it","product_cat-switches","first","instock","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"brands":[{"id":3284,"name":"RUIJIE","slug":"ruijie"}],"_links":{"self":[{"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product\/83958","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/comments?post=83958"}],"wp:attachment":[{"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/media?parent=83958"}],"wp:term":[{"taxonomy":"pwb-brand","embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/pwb-brand?post=83958"},{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product_brand?post=83958"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product_cat?post=83958"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product_tag?post=83958"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}