{"id":84100,"date":"2026-10-25T20:33:22","date_gmt":"2026-10-25T20:33:22","guid":{"rendered":"https:\/\/servicenternetwork.com\/tienda\/producto\/detector-de-humo-por-aspiracion-propointplus-1-tubo-2500-m2-scd-optico-y-co-oled-tcp-ip-en-54-20\/"},"modified":"2026-10-25T20:33:22","modified_gmt":"2026-10-25T20:33:22","slug":"detector-de-humo-por-aspiracion-propointplus-1-tubo-2500-m2-scd-optico-y-co-oled-tcp-ip-en-54-20","status":"publish","type":"product","link":"https:\/\/servicenternetwork.com\/tienda\/producto\/detector-de-humo-por-aspiracion-propointplus-1-tubo-2500-m2-scd-optico-y-co-oled-tcp-ip-en-54-20\/","title":{"rendered":"Detector de Humo por Aspiracion \/ ProPointPlus 1 Tubo \/ 2500 m2 \/ SCD Optico y CO \/ OLED \/ TCP\/IP \/ EN 54-20"},"content":{"rendered":"<div style=\"width: 100%;margin: 0 auto;font-family: sans-serif;line-height: 1.6;color: inherit;background-color: transparent\"><!-- ========== HERO ========== --><\/p>\n<div style=\"text-align: center;padding: 40px 20px 30px\">\n<p style=\"font-size: 14px;letter-spacing: 2px;opacity: 0.6;margin-bottom: 10px\">SAFE FIRE DETECTION &#183; 61986104FMULOP1 &#183; Deteccion de Fuego<\/p>\n<h2 style=\"font-size: 32px;font-weight: normal;margin: 0 auto 15px;max-width: 700px;color: inherit\">El aire habla antes que el fuego.<\/h2>\n<p style=\"font-size: 17px;opacity: 0.85;max-width: 650px;margin: 0 auto 25px\">ProPointPlus detecta humo por aspiracion continua. Muestrea el aire&amp;comma; lo analiza con sensores opticos y de CO&amp;comma; y confirma alarmas reales con algoritmos que descartan el ruido. Hasta 2&amp;comma;500 m2 de cobertura con cuatro modulos SCD enchufables en un solo equipo.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/imagenes_syscom\/AI\/agente\/ai_1788972667966_yol2hs.png\" alt=\"ProPointPlus Detector de Humo por Aspiracion\" style=\"width: 100%;max-width: 800px;border-radius: 12px;margin: 0 auto;display: block\" \/><\/div>\n<p><!-- ========== STATS RIBBON ========== --><\/p>\n<div style=\"display: flex;flex-wrap: wrap;justify-content: center;gap: 20px;padding: 30px 20px;0.2);0.2);margin-bottom: 40px\">\n<div style=\"text-align: center;min-width: 120px\">\n<p style=\"font-size: 32px;font-weight: bold;margin: 0;color: inherit\">2&amp;comma;500<\/p>\n<p style=\"font-size: 13px;opacity: 0.6;margin: 2px 0 0\">m2 cobertura<\/p>\n<\/div>\n<div style=\"text-align: center;min-width: 120px\">\n<p style=\"font-size: 32px;font-weight: bold;margin: 0;color: inherit\">0.12%<\/p>\n<p style=\"font-size: 13px;opacity: 0.6;margin: 2px 0 0\">sensibilidad \/m<\/p>\n<\/div>\n<div style=\"text-align: center;min-width: 120px\">\n<p style=\"font-size: 32px;font-weight: bold;margin: 0;color: inherit\">EN 54-20<\/p>\n<p style=\"font-size: 13px;opacity: 0.6;margin: 2px 0 0\">certificacion<\/p>\n<\/div>\n<div style=\"text-align: center;min-width: 120px\">\n<p style=\"font-size: 32px;font-weight: bold;margin: 0;color: inherit\">IP30<\/p>\n<p style=\"font-size: 13px;opacity: 0.6;margin: 2px 0 0\">proteccion<\/p>\n<\/div>\n<div style=\"text-align: center;min-width: 120px\">\n<p style=\"font-size: 32px;font-weight: bold;margin: 0;color: inherit\">TCP\/IP<\/p>\n<p style=\"font-size: 13px;opacity: 0.6;margin: 2px 0 0\">conectividad<\/p>\n<\/div>\n<\/div>\n<p><!-- ========== PILAR 1: ASPIRACION CONTINUA ========== --><\/p>\n<div style=\"display: flex;flex-wrap: wrap;align-items: center;gap: 40px;max-width: 1100px;margin: 0 auto 50px;padding: 0 20px\">\n<div style=\"flex: 1 1 400px\">\n<p style=\"font-size: 14px;letter-spacing: 1px;opacity: 0.5;margin-bottom: 8px\">DETECCION POR ASPIRACION<\/p>\n<h3 style=\"font-size: 26px;font-weight: normal;margin: 0 0 15px;color: inherit\">No espera el humo. Lo busca.<\/h3>\n<p style=\"font-size: 16px;opacity: 0.85;margin: 0\">Un ventilador interno extrae aire continuamente por tuberia de 25 mm. Cada punto de muestreo es un sensor activo. En espacios abiertos&amp;comma; los puntos se colocan cada 9 m; en ductos HVAC&amp;comma; cada 15 a 30 cm. La deteccion por aspiracion identifica humo antes que cualquier detector puntual.<\/p>\n<\/div>\n<div style=\"flex: 1 1 400px\"><img decoding=\"async\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/imagenes_syscom\/AI\/agente\/ai_1788972646920_inm25k.png\" alt=\"ProPointPlus instalado en data center con tuberia de muestreo\" style=\"width: 100%;border-radius: 12px;display: block\" \/><\/div>\n<\/div>\n<p><!-- ========== PILAR 2: MODULOS SCD ========== --><\/p>\n<div style=\"0.08);padding: 50px 20px;margin-bottom: 50px\">\n<div style=\"max-width: 1100px;margin: 0 auto\">\n<p style=\"font-size: 14px;letter-spacing: 1px;opacity: 0.5;margin-bottom: 8px;text-align: center\">MODULOS SCD ENCHUFABLES<\/p>\n<h3 style=\"font-size: 26px;font-weight: normal;margin: 0 0 15px;color: inherit;text-align: center\">Optico o CO. Tu eliges.<\/h3>\n<p style=\"font-size: 16px;opacity: 0.85;max-width: 600px;margin: 0 auto 30px;text-align: center\">Hasta cuatro detectores Scatter Chamber Detector en un solo recinto. Cada modulo es enchufable: optico puro o combinado optico\/CO mejorado. El sensor de CO es ideal para salas pequenas donde la deteccion temprana de combustion latente es critica.<\/p>\n<div style=\"display: flex;flex-wrap: wrap;justify-content: center;gap: 20px\">\n<div style=\"flex: 1 1 250px;max-width: 300px;0.3);border-radius: 12px;padding: 25px;text-align: center\">\n<p style=\"font-size: 36px;font-weight: bold;margin: 0 0 5px;color: inherit\">4<\/p>\n<p style=\"font-size: 14px;opacity: 0.7;margin: 0\">modulos SCD por equipo<\/p>\n<\/div>\n<div style=\"flex: 1 1 250px;max-width: 300px;0.3);border-radius: 12px;padding: 25px;text-align: center\">\n<p style=\"font-size: 36px;font-weight: bold;margin: 0 0 5px;color: inherit\">800<\/p>\n<p style=\"font-size: 14px;opacity: 0.7;margin: 0\">m2 por tuberia (max.)<\/p>\n<\/div>\n<div style=\"flex: 1 1 250px;max-width: 300px;0.3);border-radius: 12px;padding: 25px;text-align: center\">\n<p style=\"font-size: 36px;font-weight: bold;margin: 0 0 5px;color: inherit\">100<\/p>\n<p style=\"font-size: 14px;opacity: 0.7;margin: 0\">m2 cobertura CO<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p><!-- ========== PILAR 3: ALGORITMOS ANTI-FALSAS ALARMAS ========== --><\/p>\n<div style=\"display: flex;flex-wrap: wrap;align-items: center;gap: 40px;max-width: 1100px;margin: 0 auto 50px;padding: 0 20px\">\n<div style=\"flex: 1 1 400px\">\n<p style=\"font-size: 14px;letter-spacing: 1px;opacity: 0.5;margin-bottom: 8px\">ALGORITMOS AVANZADOS<\/p>\n<h3 style=\"font-size: 26px;font-weight: normal;margin: 0 0 15px;color: inherit\">Solo alarmas reales.<\/h3>\n<p style=\"font-size: 16px;opacity: 0.85;margin: 0\">La toma de decisiones es independiente e integrada. Algoritmos complejos amplian el rango de deteccion de particulas&amp;comma; confirman alarmas genuinas y reducen las no deseadas. Cada canal evalua su propia area de deteccion por separado. El resultado: menos interrupciones&amp;comma; mas confianza.<\/p>\n<\/div>\n<div style=\"flex: 1 1 400px\"><img decoding=\"async\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/BancoFotografiasSyscom\/AI\/UPSCALE\/212816\/portada_0S2000.PNG\" alt=\"ProPointPlus panel frontal con display OLED\" style=\"width: 100%;border-radius: 12px;display: block\" \/><\/div>\n<\/div>\n<p><!-- ========== PILAR 4: CONFIGURACION SIN LAPTOP ========== --><\/p>\n<div style=\"display: flex;flex-wrap: wrap;align-items: center;gap: 40px;max-width: 1100px;margin: 0 auto 50px;padding: 0 20px\">\n<div style=\"flex: 1 1 400px\">\n<p style=\"font-size: 14px;letter-spacing: 1px;opacity: 0.5;margin-bottom: 8px\">CONFIGURACION<\/p>\n<h3 style=\"font-size: 26px;font-weight: normal;margin: 0 0 15px;color: inherit\">Pantalla OLED. Sin computadora.<\/h3>\n<p style=\"font-size: 16px;opacity: 0.85;margin: 0\">La configuracion de sensibilidad Clase A&amp;comma; B o C se realiza desde la pantalla OLED multilenguaje. El instalador ajusta la sensibilidad equivalente a un numero conocido de detectores puntuales. La velocidad del ventilador y el flujo de aire se configuran en el mismo menu. Para avanzado&amp;comma; software ProView via TCP\/IP o USB.<\/p>\n<\/div>\n<div style=\"flex: 1 1 400px\">\n<div style=\"0.3);border-radius: 12px;padding: 30px\">\n<p style=\"font-size: 15px;opacity: 0.8;margin: 0 0 15px\"><strong>Clase A:<\/strong> max 3 orificios por tuberia &#8211; Alarma mayor o igual a 2.9%<\/p>\n<p style=\"font-size: 15px;opacity: 0.8;margin: 0 0 15px\"><strong>Clase B:<\/strong> max 5 orificios por tuberia &#8211; Alarma mayor o igual a 3.6%<\/p>\n<p style=\"font-size: 15px;opacity: 0.8;margin: 0 0 15px\"><strong>Clase C:<\/strong> max 8 orificios por tuberia &#8211; Alarma mayor o igual a 3.6%<\/p>\n<p style=\"font-size: 15px;opacity: 0.8;margin: 0\"><strong>Prision:<\/strong> max 1 orificio por tuberia<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p><!-- ========== APLICACIONES ========== --><\/p>\n<div style=\"max-width: 1100px;margin: 0 auto 50px;padding: 0 20px\">\n<h3 style=\"font-size: 22px;font-weight: normal;text-align: center;margin-bottom: 30px;color: inherit\">Disenado para donde los detectores puntuales no llegan<\/h3>\n<div style=\"display: flex;flex-wrap: wrap;gap: 20px\">\n<div style=\"flex: 1 1 200px;0.3);border-radius: 12px;padding: 25px;text-align: center\">\n<p style=\"font-size: 18px;font-weight: bold;margin: 0 0 8px;color: inherit\">Data Centers<\/p>\n<p style=\"font-size: 14px;opacity: 0.7;margin: 0\">Deteccion temprana en salas de servidores<\/p>\n<\/div>\n<div style=\"flex: 1 1 200px;0.3);border-radius: 12px;padding: 25px;text-align: center\">\n<p style=\"font-size: 18px;font-weight: bold;margin: 0 0 8px;color: inherit\">HVAC y Ductos<\/p>\n<p style=\"font-size: 14px;opacity: 0.7;margin: 0\">Muestreo cada 15 a 30 cm en ductos<\/p>\n<\/div>\n<div style=\"flex: 1 1 200px;0.3);border-radius: 12px;padding: 25px;text-align: center\">\n<p style=\"font-size: 18px;font-weight: bold;margin: 0 0 8px;color: inherit\">Almacenes<\/p>\n<p style=\"font-size: 14px;opacity: 0.7;margin: 0\">Espacios abiertos hasta 2&amp;comma;500 m2<\/p>\n<\/div>\n<div style=\"flex: 1 1 200px;0.3);border-radius: 12px;padding: 25px;text-align: center\">\n<p style=\"font-size: 18px;font-weight: bold;margin: 0 0 8px;color: inherit\">Plafones<\/p>\n<p style=\"font-size: 14px;opacity: 0.7;margin: 0\">Capilares desde tuberia a techo falso<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p><!-- ========== ESPECIFICACIONES ========== --><\/p>\n<div style=\"max-width: 1100px;margin: 0 auto 50px;padding: 0 20px\">\n<h3 style=\"font-size: 22px;font-weight: normal;border-bottom: 2px solid currentColor;padding-bottom: 5px;margin-bottom: 25px;color: inherit;opacity: 0.8\">Especificaciones Tecnicas<\/h3>\n<div style=\"display: flex;flex-wrap: wrap;gap: 20px\">\n<div style=\"flex: 1 1 250px;0.3);border-radius: 8px;overflow: hidden\">\n<div style=\"padding: 15px;0.2);font-weight: bold;font-size: 16px;color: inherit;0.05)\">Electricas<\/div>\n<div style=\"padding: 15px\">\n<dl style=\"margin: 0;font-size: 14px;color: inherit\">\n<dt style=\"font-weight: bold;margin-top: 8px\">Alimentacion:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">21-28 VDC&amp;comma; min. 2 A (EN54-4)<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Consumo max.:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">600 mA a 24 VDC<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Fusible:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">1.6 A<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Entradas:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">3 programables monitoreadas<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Salidas:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">5 contactos secos programables<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Conectividad:<\/dt>\n<dd style=\"margin: 0;opacity: 0.8\">TCP\/IP (RJ45) + USB Type B<\/dd>\n<\/dl>\n<\/div>\n<\/div>\n<div style=\"flex: 1 1 250px;0.3);border-radius: 8px;overflow: hidden\">\n<div style=\"padding: 15px;0.2);font-weight: bold;font-size: 16px;color: inherit;0.05)\">Deteccion<\/div>\n<div style=\"padding: 15px\">\n<dl style=\"margin: 0;font-size: 14px;color: inherit\">\n<dt style=\"font-weight: bold;margin-top: 8px\">Sensibilidad:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">0.12%\/m a 11%\/m<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Cobertura por tubo:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">800 m2 (Clase C8)<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Cobertura total:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">2&amp;comma;500 m2 (4 tubos)<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Cobertura CO:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">100 m2<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Modulos SCD:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">Hasta 4 enchufables<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Norma:<\/dt>\n<dd style=\"margin: 0;opacity: 0.8\">BS EN 54-20:2006<\/dd>\n<\/dl>\n<\/div>\n<\/div>\n<div style=\"flex: 1 1 250px;0.3);border-radius: 8px;overflow: hidden\">\n<div style=\"padding: 15px;0.2);font-weight: bold;font-size: 16px;color: inherit;0.05)\">Tuberia<\/div>\n<div style=\"padding: 15px\">\n<dl style=\"margin: 0;font-size: 14px;color: inherit\">\n<dt style=\"font-weight: bold;margin-top: 8px\">Diametro tubo:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">25 mm OD<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Longitud max.:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">200 m (confirmar con software)<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Velocidad flujo:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">0.5 a 6 m\/s<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Monitoreo flujo:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">Alto y bajo (+\/-5% a 50%)<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Puntos muestreo:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">Cada 9 m (alt. menor o igual a 9 m)<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">En ductos:<\/dt>\n<dd style=\"margin: 0;opacity: 0.8\">Cada 15 a 30 cm<\/dd>\n<\/dl>\n<\/div>\n<\/div>\n<div style=\"flex: 1 1 250px;0.3);border-radius: 8px;overflow: hidden\">\n<div style=\"padding: 15px;0.2);font-weight: bold;font-size: 16px;color: inherit;0.05)\">Fisicas<\/div>\n<div style=\"padding: 15px\">\n<dl style=\"margin: 0;font-size: 14px;color: inherit\">\n<dt style=\"font-weight: bold;margin-top: 8px\">Dimensiones:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">380 x 250 x 137 mm<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Peso:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">3 kg<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Temperatura:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">0 a 45 grados C<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Humedad:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">0-95% no condensante<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Proteccion:<\/dt>\n<dd style=\"margin: 0 0 4px;opacity: 0.8\">IP30<\/dd>\n<dt style=\"font-weight: bold;margin-top: 8px\">Display:<\/dt>\n<dd style=\"margin: 0;opacity: 0.8\">OLED multilenguaje<\/dd>\n<\/dl>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p><!-- ========== CIERRE ========== --><\/p>\n<div style=\"text-align: center;max-width: 700px;margin: 0 auto 40px;padding: 30px 20px\">\n<p style=\"font-size: 14px;letter-spacing: 1px;opacity: 0.5;margin-bottom: 10px\">COMPATIBILIDAD Y SOPORTE<\/p>\n<h3 style=\"font-size: 24px;font-weight: normal;margin: 0 0 15px;color: inherit\">Protocolo Protec Algo-tec 6000. Software ProView incluido.<\/h3>\n<p style=\"font-size: 16px;opacity: 0.85;margin: 0\">Registro de 256 eventos FIFO&amp;comma; historial ambiental de un mes&amp;comma; indicadores LED para estado y alarma. Configuracion via display o PC. Tres anos de garantia.<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Marca <b>SAFE FIRE DETECTION INC.<\/b> \u00b7 Modelo <b>61986104-FMULOP1<\/b><\/p>\n<p>Producto original con garant\u00eda de f\u00e1brica. Precio con IVA incluido.<\/p>\n","protected":false},"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":[],"pwb-brand":[3288],"product_brand":[],"product_cat":[3003,2832,3004],"product_tag":[],"class_list":["post-84100","product","type-product","status-publish","pwb-brand-safe-fire-detection-inc","product_cat-aplicaciones-especiales","product_cat-deteccion-de-fuego","product_cat-detectores-por-aspiracion","first","instock","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"brands":[{"id":3288,"name":"SAFE FIRE DETECTION INC.","slug":"safe-fire-detection-inc"}],"_links":{"self":[{"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product\/84100","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/comments?post=84100"}],"wp:attachment":[{"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/media?parent=84100"}],"wp:term":[{"taxonomy":"pwb-brand","embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/pwb-brand?post=84100"},{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product_brand?post=84100"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product_cat?post=84100"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/servicenternetwork.com\/tienda\/wp-json\/wp\/v2\/product_tag?post=84100"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}